Skip to main content

Plasma is ineffective in correcting mildly elevated PT-INR in critically ill children: a retrospective observational study

Abstract

Background

Fresh frozen plasma transfusion is widely utilized in pediatric clinical practice to correct mild coagulopathy. Several studies on adult population have shown that transfusion of plasma cannot effectively correct mild coagulopathy when international normalized ratio (INR) is ≤1.5. Much controversy exists about the generalization of this finding for pediatric populations, especially since pediatric dosages often exceed those in adults. The aim of this study is to determine the prevalence of plasma transfusion with mild coagulopathy (INR ≤ 1.5) and its effectiveness in a pediatric setting.

Methods

In our tertiary referral hospital, we retrospectively reviewed the electronic medical records of all patients who received plasma (April to October 2011) for mildly elevated prothrombin time (PT)-INR levels (≤1.5) and had post-transfusion PT-INR measurements; patients who received intraoperative, ECMO, or plasma exchange-related plasma transfusions were excluded from this study. We abstracted demographic data and pre- and post coagulation test results for the patients included in our study.

Results

Among 468 plasma transfusions administered to 285 patients from April to June 2011, 60 plasma transfusions (12.8%) were given to patients with PT-INR ≤ 1.5 (range 1.3–1.5). Forty-one patients [median age 2.5 years (IQR, 0.14 to 13.75 years), median weight of 16.0 kg (IQR, 8.0 to 69.3 kg)] who received 41 single plasma transfusions [median dose 11 mL/Kg (IQR, 6–15)] had post-transfusion PT-INR measurements and were included in our study. There was no significant difference in their PT-INR values (p = 0.34) pre- and post-transfusion. Of our study, only 15.4% patients showed post-transfusion normalization [median change in PT-INR 0.15 (IQR, 0.1–0.2)] and were not different from the remaining 85% in age, plasma dose, and bleeding status.

Conclusions

The prevalence of plasma transfusion for correction of mildly elevated PT-INR levels in critically ill children is high (12.8%). Plasma transfusion showed no significant effect in correcting minor prolongation of PT-INR in pediatric patients regardless of age, volume of plasma transfused per kilogram (dosage), or bleeding status.

Background

Fresh frozen plasma (FFP) constitutes a ready supply of plasma proteins, most notably the coagulation-related factors. Its utilization resides chiefly in replenishing coagulation factors in any clinical setting with ongoing or suspected coagulopathy. As can be expected from a product with broad indications, plasma usage in the United States is expanding and evolving along with medical and surgical support capabilities. In particular, studies of plasma use in pediatric intensive care units (PICUs) demonstrate more frequent use of plasma to support volume expansion, massive hemorrhage, liver disease, disseminated intravascular coagulation, and correction of prolonged clotting tests, among other clinical indications [1]. Appropriate use of plasma is indicated in massive hemorrhage, liver disease, and disseminated intravascular coagulopathy (DIC) with bleeding in pediatric intensive care settings [1],[2]. Its role as an effective prophylactic agent, however, has been disputed when used prior to invasive procedures such as liver biopsy and central line placement, with no correlation found between bleeding risk and pre-procedure coagulation test results [3],[4]. In addition, plasma transfusion carries its own host of complications, including disease transmission, allergic reactions, alloimmunization, volume overload, thrombosis, multiple organ failure, and transfusion-related acute lung injury (TRALI) [5]-[10]. The majority of studies evaluating outcome of plasma transfusion in specific clinical scenarios, particularly in neonates, have prompted the recent publication of guidelines to curtail plasma transfusion for mild coagulation abnormalities in children [11]. According to recent transfusion data issued by hospitals in the United States, the United Kingdom, and Canada, prescribing plasma inappropriately is a common practice, despite published guidelines [12],[13].

The current plasma transfusion practice for the purpose of correcting mildly prolonged coagulation tests is of interest to our institution, the largest pediatric hospital in the United States. Published studies on adult plasma transfusion have shown minimal to no effect when used either prophylactically or as a therapeutic agent for bleeding when the international normalized ratio (INR) is ≤1.5 [14]-[16]. Puetz et al. recently demonstrated pediatric United States hospitals to have a high prevalence of plasma transfusion in critically ill children but did not evaluate the indications for transfusion [17]. We set out to evaluate the local transfusion practice with respect to plasma by: 1) determining the frequency of plasma transfusions and 2) assessing the significance of improvements in coagulation tests [prothrombin time-international normalized ratio (PT-INR)] in the context of the clinical scenario via the electronic medical record. In the United States, most transfusion guidelines are established locally by varying methods within each institution. However, it is prudent that plasma transfusion guidelines be based on the aggregate of local, national, and population-specific evidence. To contribute, we retrospectively evaluated the effect of plasma transfusions on mild elevations of PT-INR often referred to clinically as “mild coagulopathy”.

Methods

After institutional review board of Baylor College of Medicine approved the study with waiver of informed consent, we conducted a retrospective analysis of transfusion and coagulation-related records from the blood bank and patient electronic medical records (EMR) at Texas Children’s Hospital for the 3-month time period from April to June of 2011. Patient chart review was performed to collect demographic and clinical details. We included all patients who: 1) had a pre-transfusion INR of 1.3 to 1.5, 2) received one or more plasma transfusions, and 3) had a post-transfusion INR checked within 8 h of transfusion. Patients receiving plasma transfusion support during extracorporeal membranous oxygenation (ECMO) or as intraoperative transfusion were excluded from the study. Demographic variables included age, weight, and patient’s location (excluding emergency department and operating rooms, all inpatient hospital units were included). The patient’s clinical description of disease along with the indication for plasma transfusion was extracted from the EMR via blood product orders and provider notes. The results of laboratory coagulation tests performed on the day of plasma transfusion including PT-INR and platelet count were extracted from the same database. Patient hemostatic conditions were categorized into bleeding or non-bleeding as documented by the clinical providers. Next, we assessed any change in the PT-INR, after plasma transfusion. Independent variables included age and body weight. PT was measured using commercial PT reagents on STA-R automatic analyzer (Diagnostica Stago Inc., Parsippany, NJ, USA).

The patient population was characterized into groups based on whether PT-INR decreased after plasma transfusion and whether hemostatic status improved (i.e., bleeding subsided). Fisher’s exact test was used to assess the association between two categorical variables such as post-transfusion decrease in INR (presence or absence), age (<1 vs. ≥1 month), plasma dose (≤10 vs. >10 cc/kg), and bleeding symptoms (bleeding vs. non-bleeding). Association between pre-transfusion PT and bleeding was also assessed. Non-parametric analysis of two related samples employed the Wilcoxon signed rank test to detect significant difference between the pre- and post-transfusion PT-INR values. Mann–Whitney test allowed determination of significant difference in different variables between two categories of patients. In order to determine if an increasing volume of plasma transfused was associated with a change in INR, patients were divided into quartiles based on total plasma volume transfused. From this data, a contingency table (4 × 2) analysis was performed and a Chi-squared (χ2) p value was calculated. P values of <0.05 were considered statistically significant.

Results

A total of 468 plasma transfusions were administered to 285 patients from April 2011 through June 2011. Among these, 60 plasma transfusions (12.8%) were given when PT-INR ≤1.5, ranging from 1.3–1.5. Forty-one patients had post-transfusion PT-INR measurements. Almost half (46.3%) of these plasma transfusions were administered to patients whose PT-INRs were within age-specific normal levels. Of the 41 patients, 39% of patients (n = 16) had documented bleeding. Nine patients (22%) were neonates (age ≤30 days) and only five of them had bleeding symptoms. Characteristics of patients (n = 41) with plasma transfusion for mildly prolonged PT-INR are listed in Table 1.

Table 1 Characteristics of patients ( n= 41) with plasma transfusion for mildly prolonged PT-INR

There was no statistically significant difference in PT-INR before and after plasma transfusion in the study population (p = 0.34) (Table 2). Transfusion of plasma resulted in normalization of PT-INR values in only 15.4% (n = 6) of patients with the remainder showing no improvement in PT-INR. Table 3 describes the characteristics of these patients. The median change in PT-INR for patients with normalization was 0.15 (IQR, 0.1–0.2). There was no statistically significant association between PT-INR normalization and higher plasma dose, younger age, or bleeding status (p = 0.18, p = 0.16, p = 0.68), respectively. Increasing plasma transfusion dose was not associated with a change in INR (p = 0.78).

Table 2 Coagulation parameters pre- and post-transfusion of plasma for all patients with INR ≤1.5
Table 3 Baseline characteristics of patients with and without normalization of PT-INR

Thirty-nine percent (n = 16) of patients were transfused with plasma during a bleeding episode. There was no significant association between pre-transfusion PT and bleeding (p = 0.70). Among these patients, the majority (69%, n = 11) were clinically deemed as mild: e.g., bleeding around the gums (n = 2), slow oozing from an incision site (n = 2), a small amount of blood in the endotracheal and nasogastric tube (n = 2) and blood-tinged chest-tube output (n = 5). The remaining five patients had clinically significant bleeding such as melena (n = 2), hemoptysis (n = 2), and epistaxis (n = 1). Four out of 16 (25%) patients showed improvement in bleeding, and it stopped in 2 out of 4 after local use of anti-fibrinolytics. Of all the bleeding patients, 12% had an improvement in PT-INR values, but were not normalized. Bleeding status was not associated with post-transfusion change in PT-INR (p = 1.0). Platelet counts were above 100,000/mL in both bleeding and non-bleeding patients (p = 0.74). The volume and dosage of plasma administered to bleeders and non-bleeders were not different (p = 0.65, p = 0.85) (Table 4).

Table 4 Baseline characteristics of patients with and without bleeding symptoms

Discussion

Despite the results of many clinical studies, clinicians still prefer to use plasma as a therapeutic or prophylactic measure to correct mildly prolonged PT-INR based on assumptions of reducing bleeding risk [15]. In our study, we sought to assess the prevalence of plasma use in pediatric inpatients and found it to be high (12.8%). Among our study population, close to half (42%) were less than 1 year old. A majority of these transfusions occurred in the ICU setting including the cardiovascular, neonatal, and pediatric ICUs. This is consistent with a recent large epidemiological study describing the pattern of plasma usage in pediatric hospitals [17]. Our data illustrates the extent of ineffective use of plasma in neonates and in critically ill children, including those with cardiac diseases. Although targeted and therapeutic plasma use in certain clinical conditions can be life-saving (e.g., support of coagulopathy), its general prophylactic benefit in critically ill children is highly doubtful and lacks evidence. In the absence of evidence-based guidelines, pediatric intensivists and physicians in other specialties must make decisions based on presumed probability of benefit to the patient.

In our study, only 39% of patients had bleeding symptoms; the majority (69%) had bleeding events considered mild due to location and very small volume of blood loss. This demonstrates that over half of the patient population with a mild elevation in PT-INR received plasma for non-bleeding causes. Frequent reasons cited in the EMR include pre-procedural prophylaxis and primary volume replacement. The platelet counts were similar in both bleeding and non-bleeding patients indicating that thrombocytopenia was unlikely to have increased concern for overall coagulopathy and therefore lowered the threshold for plasma transfusion. We found no significant association between pre-transfusion PT-INR and bleeding.

Recent evidence-based recommendations for plasma transfusion include: correction of coagulopathy related to DIC, vitamin K, and inherited deficiencies of clotting factors resulting in bleeding [1]. However, our findings and experience suggest that plasma transfusion to attempt correction of an INR <1.5 is a common practice. Although it is not well-documented in the literature, there is a common assumption albeit false that a small increase in INR will reliably predict bleeding risk and that clotting factors in plasma will correct this “derangement” and protect from bleeding. Additionally, there are no pediatric randomized control studies on mild elevation of INR during procedures that offer definite evidence of predictive ability with respect to bleeding. It is also critical, when evaluating hemostasis in neonates, that age-specific normal ranges are determined and referenced. In our study, neonates received 22% (9/41) of transfusions, only half of those with bleeding or potential coagulopathy. Pre-transfusion INR values were all within age-specific normal ranges. It is not surprising that none of these patients had a post-transfusion change in INR. In comparison to adult coagulation times, neonates normally have “more prolonged” coagulation times. The prolongation is usually mild and is not considered pathologic or carrying increased risk of bleeding. Therefore, mildly abnormal coagulation tests without bleeding or strong clinical indicators of coagulopathy should be confirmed abnormal for age and are not an independent indication for plasma therapy in neonates [18].

Our study of pediatric patients [5 (0.14–13.75) median age (IQR) years] examined the effect of plasma transfusion on PT-INR. We found that of the 16% of patients with a post-plasma transfusion change in PT-INR, the change was negligible regardless of increasing dose. We found no significant association between pre-transfusion PT and bleeding. Abdel-Wahab et al. report that plasma corrected INR in only about 16% of adult ICU patients with initial mild elevation in PT-INR in Massachusetts General Hospital [19]. Holland et al. also found insignificant changes in INR results in both pediatric and adult study populations receiving plasma for INR elevations ≤1.5 [20]. Segal et al. systematically reviewed multiple studies and found inadequate proof to determine that abnormal coagulation test results predict bleeding [16]. In a recent review of prophylactic “correction” of INR prior to neurosurgery, the authors concluded that there is no added benefit of plasma transfusion in a non-bleeding patient with mildly prolonged INR [14]. A systematic review published in 2005 identified 25 adult studies, among which none found an association of mildly prolonged coagulation variables with increased risk of bleeding [16]. Thirty percent coagulation factor activity is necessary for maintaining hemostasis. However, Burns et al. demonstrated that prolongation in INR occurs at 50% reduction of multiple coagulation factor activity [21]. Due to assay design and potential interfering clinical factors, PT-INR is an insensitive predictor of low factor levels in critically ill adults, which in part explains their inability to predict bleeding [22].

This study is among very few in the pediatric literature that addresses effectiveness of plasma transfusion for mildly prolonged PT-INR. The results of our study are based on retrospective data, which has an inherent disadvantage in documentation. However, this issue is somewhat mitigated by the bulk of the study being focused on the pre- and post-transfusion delta in INR, which is easily and accurately mined from the laboratory information system or EMR. For a future study with more emphasis on outcomes, we would include a non-transfused patient control group with mildly prolonged coagulation tests for outcome comparison, e.g., peri- or post-procedural bleeding. However, our results signify the effect of plasma transfusion in pediatric patients: plasma transfusion does not significantly improve mildly prolonged PT-INR. This applies to bleeding and non-bleeding patients with the exception of a rapidly bleeding or evolving coagulopathic scenario. In these settings, a mild abnormality may become a serious deficiency during the lag time between specimen collection and reporting of results. Guidelines on the appropriateness of plasma transfusion, as well as relevant test limitations, should be evidence-based when those tests are used as transfusion triggers. Optimal patient care requires pediatric critical care physicians to be aware of low-to-no benefit and potential harm of plasma therapy for mild coagulation abnormalities without supporting indications. Further research, including randomized control trials, is necessary to provide robust evidence for guiding plasma use in children.

Conclusion

Plasma transfusion in critically ill children does not significantly correct mildly prolonged PT-INR. Pediatric intensivists should avoid prescribing plasma transfusion for an isolated mild increase in PT-INR values with an aim of preventing or controlling bleeding episodes. Guidelines to optimize its use should be formulated based on prospective clinical trials of plasma transfusions with emphasis on transfusion triggers and outcomes related to both bleeding and adverse transfusion reactions.

Authors’ information

JT is a Professor of Pathology and Immunology, Pediatrics and Medicine; Vice Chairman for Education; Director, Transfusion Medicine/Blood Banking Fellowship Program (Baylor College of Medicine); and Director, Division of Transfusion Medicine and Coagulation (Texas Children’s Hospital). SRH is an Assistant Professor for Clinical Pathology, Baylor College of Medicine; Director of Blood Bank of Pavilion for Women; and Assistant Director of Division of Transfusion Medicine and Coagulation (Texas Children’s Hospital). SKH is an Assistant Professor, Pathology and Immunology (Baylor College of Medicine); Associate Director-Clinical Pathology (Pathology Residency Program); Assistant Director of Transfusion Medicine and Coagulation (Texas Children’s Hospital); and Medical Director, Blood Bank (Texas Children’s Hospital-West Campus).

Abbreviations

INR:

international normalized ratio

PT:

prothrombin time

FFP:

fresh frozen plasma

ECMO:

extracorporeal membrane oxygenator

PICU:

pediatric intensive care unit

EMR:

electronic medical record

TRALI:

transfusion related acute lung injury

DIC:

disseminated intravascular coagulation

References

  1. Goldenberg NA, Manco-Johnson MJ: Pediatric hemostasis and use of plasma components. Best Pract Res Clin Haematol 2006, 19: 143-155. 10.1016/j.beha.2005.03.006

    Article  CAS  PubMed  Google Scholar 

  2. Motta M, Del Vecchio A, Radicioni M: Clinical use of fresh-frozen plasma and cryoprecipitate in neonatal intensive care unit. J Matern Fetal Neonatal Med 2011,24(Suppl 1):129-131. 10.3109/14767058.2011.607677

    Article  PubMed  Google Scholar 

  3. Gajic O, Dzik WH, Toy P: Fresh frozen plasma and platelet transfusion for non-bleeding patients in the intensive care unit: benefit or harm? Crit Care Med 2006,34(Suppl 5):170-173. 10.1097/01.CCM.0000214288.88308.26

    Article  Google Scholar 

  4. Stanworth SJ, Walsh TS, Prescott RJ, Lee RJ, Watson DM, Wyncoll D: A national study of plasma use in critical care: clinical indications, dose and effect on prothrombin time. Crit Care 2011,15(2):R108. 10.1186/cc10129

    Article  PubMed  PubMed Central  Google Scholar 

  5. Bolton-Maggs PH, Cohen H: Serious hazards of transfusion (SHOT) haemovigilance and progress is improving transfusion safety. Br J Hematol 2013, 163: 303-314. 10.1111/bjh.12547

    Article  Google Scholar 

  6. Vamvakas EC, Blajchman MA: Transfusion-related mortality: the ongoing risks of allogeneic blood transfusion and the available strategies for their prevention. Blood 2009, 113: 3406-3417. 10.1182/blood-2008-10-167643

    Article  CAS  PubMed  Google Scholar 

  7. Rana R, Fernandez-Perez ER, Khan SA, Rana S, Winters JL, Lesnick TG, Moore SB, Gajic O: Transfusion-related acute lung injury and pulmonary edema in critically ill patients: a retrospective study. Transfusion 2006,46(9):1478-1483. 10.1111/j.1537-2995.2006.00930.x

    Article  PubMed  Google Scholar 

  8. Abbott LS, Deevska M, Fernandez CV, Dix D, Price VE, Wang H, Parker L, Yhap M, Fitzgerald C, Barnard DR, Berman JN: The impact of prophylactic fresh-frozen plasma and cryoprecipitate on the incidence of central nervous system thrombosis and hemorrhage in children with acute lymphoblastic leukemia receiving asparaginase. Blood 2009,10(114(25)):5146-5151. 10.1182/blood-2009-07-231084

    Article  Google Scholar 

  9. Church GD, Matthay MA, Liu K, Milet M, Flori HR: Blood product transfusions and clinical outcomes in pediatric patients with acute lung injury. Pediatr Crit Care Med 2009,10(3):297-302. 10.1097/PCC.0b013e3181988952

    Article  PubMed  PubMed Central  Google Scholar 

  10. Watson GA, Sperry JL, Rosengart MR, Minei JP, Harbrecht BG, Moore EE, Cuschieri J, Maier RV, Billiar TR, Peitzman AB: Fresh frozen plasma is independently associated with a higher risk of multiple organ failure and acute respiratory distress syndrome. J Trauma 2009,67(2):221-230. 10.1097/TA.0b013e3181ad5957

    Article  PubMed  Google Scholar 

  11. Contreras M, Ala FA, Greaves M, Jones J, Levin M, Machin SJ, Morgan C, Murphy W, Napier JA, Thomson AR: Guidelines for the use of fresh frozen plasma. British Committee for Standards in Hematology, Working Party of the Blood Transfusion Task Force. Transfus Med 1992,2(1):57-63. 10.1111/j.1365-3148.1992.tb00135.x

    Article  CAS  PubMed  Google Scholar 

  12. Stanworth SJ, Grant-Casey J, Lowe D, Laffan M, New H, Murphy MF, Allard S: The use of fresh-frozen plasma in England: high levels of inappropriate use in adults and children. Transfusion 2011,51(1):62-70. 10.1111/j.1537-2995.2010.02798.x

    Article  PubMed  Google Scholar 

  13. Tinmouth A, Thompson T, Arnold DM, Callum JL, Gagliardi K, Lauzon D, Owens W, Pinkerton P: Utilization of frozen plasma in Ontario: a provincewide audit reveals a high rate of inappropriate transfusions. Transfusion 2013, 53: 2222-2229.

    PubMed  Google Scholar 

  14. West KL, Adamson C, Hoffman M: Prophylactic correction of the international normalized ratio in neurosurgery: a brief review of a brief literature. J Neurosurg 2011, 114: 9-18. 10.3171/2010.7.JNS091857

    Article  PubMed  Google Scholar 

  15. Stanworth SJ, Brunskill SJ, Hyde CJ, McClelland DB, Murphy MF: Is fresh frozen plasma clinically effective? A systematic review of randomized controlled trials. Br J Hematol 2004, 126: 139-152. 10.1111/j.1365-2141.2004.04973.x

    Article  CAS  Google Scholar 

  16. Segal JB, Dzik WH: Transfusion Medicine/Hemostasis Clinical Trials Network. Paucity of studies to support that abnormal coagulation test results predict bleeding in the setting of invasive procedures: an evidence-based review. Transfusion 2005, 45: 1413-1425. 10.1111/j.1537-2995.2005.00546.x

    Article  PubMed  Google Scholar 

  17. Puetz J, Witmer C, Huang YS, Raffini L: Widespread use of fresh frozen plasma in US children’s hospitals despite limited evidence demonstrating a beneficial effect. J Pediat 2012, 160: 210-215. 10.1016/j.jpeds.2011.08.013

    Article  PubMed  Google Scholar 

  18. Muntean W: Fresh frozen plasma in the pediatric age group and in congenital coagulation factor deficiency. Thromb Res 2002,107(Suppl 1):29-32. 10.1016/S0049-3848(02)00149-4

    Article  Google Scholar 

  19. Abdel-Wahab OI, Healy B, Dzik WH: Effect of fresh-frozen plasma transfusion on prothrombin time and bleeding in patients with mild coagulation abnormalities. Transfusion 2006, 46: 1279-1285. 10.1111/j.1537-2995.2006.00891.x

    Article  PubMed  Google Scholar 

  20. Holland L, Sarode R: Should plasma be transfused prophylactically before invasive procedures? Curr Opin Hematol 2006, 13: 447-451. 10.1097/01.moh.0000245688.47333.b6

    Article  PubMed  Google Scholar 

  21. Burns ER, Goldberg SN, Wenz B: Paradoxic effect of multiple mild coagulation factor deficiencies on the prothrombin time and activated partial thromboplastin time. Am J Clin Pathol 1993, 100: 94-98.

    CAS  PubMed  Google Scholar 

  22. Chowdary P, Saayman AG, Paulus U, Findlay GP, Collins PW: Efficacy of standard dose and 30 ml/kg fresh frozen plasma in correcting laboratory parameters of hemostasis in critically ill patients. Br J Hematol 2004, 125: 69-73. 10.1111/j.1365-2141.2004.04868.x

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Shiu-Ki Rocky Hui.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

ES was responsible for the study design, data analysis, and manuscript writing. RB was responsible for the study design, execution, and data collection. SRH, JT, and SKH were also involved in the study design and execution and data analysis and provided advice during write-up. All authors read and approved the final manuscript.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Soundar, E.P., Besandre, R., Hartman, S.K. et al. Plasma is ineffective in correcting mildly elevated PT-INR in critically ill children: a retrospective observational study. j intensive care 2, 64 (2014). https://doi.org/10.1186/s40560-014-0064-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40560-014-0064-1

Keywords